Valves

2-Port Valve

In short

2-Port Valve: Zone valve with end switch (5-wire: E/N/B/Grey/Orange). It has 5 terminals: E (Earth), N (Neutral), B (Brown), G (Grey), O (Orange).

If this is your home: this page is written for heating engineers. Mains wiring and gas appliances are not DIY jobs; call a Gas Safe registered engineer. If you smell gas, leave the building and call the National Gas Emergency Service on 0800 111 999.

2-Port Valve as drawn in the simulator

Terminals

TerminalWhat it isOn an S-PlanOn a Y-Plan
EEarthWiring centre terminal 3 (earth)—
NNeutralWiring centre terminal 2 (neutral)—
BBrownHeating valve: Wiring centre terminal 5 (room stat call). Hot water valve: Wiring centre terminal 8 (cylinder stat call)—
GGreyWiring centre terminal 1 (permanent live)—
OOrangeWiring centre terminal 10 (switched live, on to the boiler SL)—

How it fails

Where it connects

Lessons that use it