Programmers/Timers

Dual Channel Programmer

In short

Dual Channel Programmer: Controls HW and CH circuits. It has 7 terminals: E (Earth), L (Live), N (Neutral), 1 (HW OFF), 2 (CH OFF), 3 (HW ON), 4 (CH ON).

If this is your home: this page is written for heating engineers. Mains wiring and gas appliances are not DIY jobs; call a Gas Safe registered engineer. If you smell gas, leave the building and call the National Gas Emergency Service on 0800 111 999.

Dual Channel Programmer as drawn in the simulator

Terminals

TerminalWhat it isOn an S-PlanOn a Y-Plan
EEarthWiring centre terminal 3 (earth)Wiring centre terminal 3 (earth)
LLiveWiring centre terminal 1 (permanent live)Wiring centre terminal 1 (permanent live)
NNeutralWiring centre terminal 2 (neutral)Wiring centre terminal 2 (neutral)
1HW OFF—Wiring centre terminal 7 (HW OFF, with the cylinder stat satisfied contact, on to the valve grey)
2CH OFF——
3HW ONWiring centre terminal 6 (HW demand, on to the cylinder thermostat common)Wiring centre terminal 6 (HW demand, on to the cylinder thermostat common)
4CH ONWiring centre terminal 4 (CH demand, on to the room thermostat L)Wiring centre terminal 4 (CH demand, on to the room thermostat L)

How it fails

Where it connects

Lessons that use it