Y-Plan · 8 parts · 27 wires

Y-Plan wiring diagram

In short

A Y-Plan is a fully pumped system with one 3-port mid-position valve. It rests at the hot water port, moves to mid-position when the room thermostat calls, and to the heating-only port when hot water is satisfied or timed off. The white and grey cores drive it; the orange core and the cylinder stat fire the boiler.

Y-Plan fully wired in the DrawWarm simulator

A working Y-Plan in the simulator. Wire colours follow BS 7671; every terminal is live, neutral, earth or dead, and the meter reads what the circuit is doing.

Wiring centre numbering

The numbering is a convention so that the next engineer can read your work. A block carries whatever you land on it; the test harness proves the same system wired on scrambled blocks.

BlockCarries
1Permanent live from the fused spur (brown)
2Neutral (blue)
3Earth (green/yellow)
4CH ON from the programmer, out to the room thermostat L
5Room thermostat call, out to the valve white
6HW ON from the programmer, out to the cylinder thermostat C
7HW OFF from the programmer and the cylinder thermostat satisfied contact, out to the valve grey
8Cylinder thermostat call and the valve orange in, boiler switched live out
9Spare
10Spare
11Spare
12Spare

Every wire, terminal by terminal (27)

#FromTerminalToTerminalColour
1Fused SpurLWiring Centre1Brown (live)
2Fused SpurNWiring Centre2Blue (neutral)
3Fused SpurEWiring Centre3Green/yellow (earth)
4Circulation PumpEWiring Centre3Green/yellow (earth)
5Dual Channel ProgrammerEWiring Centre3Green/yellow (earth)
6Circulation PumpNWiring Centre2Blue (neutral)
7Room ThermostatNWiring Centre2Blue (neutral)
8Dual Channel ProgrammerNWiring Centre2Blue (neutral)
9Wiring Centre1Dual Channel ProgrammerLBrown (live)
10Dual Channel Programmer4Wiring Centre4Brown (live)
11Wiring Centre4Room ThermostatLBrown (live)
12Room ThermostatSLWiring Centre5Brown (live)
13Dual Channel Programmer3Wiring Centre6Brown (live)
14Cylinder Thermostat BCWiring Centre6Brown (live)
15Dual Channel Programmer1Wiring Centre7Brown (live)
16Cylinder Thermostat B2Wiring Centre8Brown (live)
17Heat-Only BoilerLWiring Centre1Brown (live)
18Heat-Only BoilerNWiring Centre2Blue (neutral)
19Heat-Only BoilerEWiring Centre3Green/yellow (earth)
20Wiring Centre8Heat-Only BoilerSLOrange
21Heat-Only BoilerPLCirculation PumpLBrown (live)
223-Port ValveEWiring Centre3Green/yellow (earth)
233-Port ValveNWiring Centre2Blue (neutral)
243-Port ValveWWiring Centre5Grey
253-Port ValveGWiring Centre7Grey
263-Port ValveOWiring Centre8Orange
27Cylinder Thermostat B1Wiring Centre7Brown (live)

The truth table it must pass

Commissioning is four demand states and four results. The test harness runs this table against the circuit before every release.

DemandResult
No demand: programmer HW off and CH off (room stat calling, cylinder cold)Valve rests at B (hot water port); boiler off
HW only: programmer HW on (room stat calling, cylinder cold)Valve stays at B (hot water port); boiler fires
CH only, HW timed off: programmer CH on (room stat calling, cylinder cold)Valve drives to A (heating port); boiler fires
CH + HW: programmer HW on and CH on (room stat calling, cylinder cold)Valve at mid position; boiler fires
CH + HW, cylinder now hot (room stat calling)Valve moves to A (heating port); boiler fires
HW on but cylinder hot, CH off (room stat calling)Boiler off (valve position not asserted by the probe)

Related

Build it lesson by lesson

  • Y-Plan Wiring course

    Master the Y-Plan system with hands-on wiring. Connect the 3-port valve and see mid-position operation in action.

If this is your home: this page is written for heating engineers. Mains wiring and gas appliances are not DIY jobs; call a Gas Safe registered engineer. If you smell gas, leave the building and call the National Gas Emergency Service on 0800 111 999.

Your first fault is waiting.