Y-Plan · 8 parts · 27 wires
Y-Plan wiring diagram
In short
A Y-Plan is a fully pumped system with one 3-port mid-position valve. It rests at the hot water port, moves to mid-position when the room thermostat calls, and to the heating-only port when hot water is satisfied or timed off. The white and grey cores drive it; the orange core and the cylinder stat fire the boiler.

A working Y-Plan in the simulator. Wire colours follow BS 7671; every terminal is live, neutral, earth or dead, and the meter reads what the circuit is doing.
Wiring centre numbering
The numbering is a convention so that the next engineer can read your work. A block carries whatever you land on it; the test harness proves the same system wired on scrambled blocks.
| Block | Carries |
|---|---|
| 1 | Permanent live from the fused spur (brown) |
| 2 | Neutral (blue) |
| 3 | Earth (green/yellow) |
| 4 | CH ON from the programmer, out to the room thermostat L |
| 5 | Room thermostat call, out to the valve white |
| 6 | HW ON from the programmer, out to the cylinder thermostat C |
| 7 | HW OFF from the programmer and the cylinder thermostat satisfied contact, out to the valve grey |
| 8 | Cylinder thermostat call and the valve orange in, boiler switched live out |
| 9 | Spare |
| 10 | Spare |
| 11 | Spare |
| 12 | Spare |
Every wire, terminal by terminal (27)
| # | From | Terminal | To | Terminal | Colour |
|---|---|---|---|---|---|
| 1 | Fused Spur | L | Wiring Centre | 1 | Brown (live) |
| 2 | Fused Spur | N | Wiring Centre | 2 | Blue (neutral) |
| 3 | Fused Spur | E | Wiring Centre | 3 | Green/yellow (earth) |
| 4 | Circulation Pump | E | Wiring Centre | 3 | Green/yellow (earth) |
| 5 | Dual Channel Programmer | E | Wiring Centre | 3 | Green/yellow (earth) |
| 6 | Circulation Pump | N | Wiring Centre | 2 | Blue (neutral) |
| 7 | Room Thermostat | N | Wiring Centre | 2 | Blue (neutral) |
| 8 | Dual Channel Programmer | N | Wiring Centre | 2 | Blue (neutral) |
| 9 | Wiring Centre | 1 | Dual Channel Programmer | L | Brown (live) |
| 10 | Dual Channel Programmer | 4 | Wiring Centre | 4 | Brown (live) |
| 11 | Wiring Centre | 4 | Room Thermostat | L | Brown (live) |
| 12 | Room Thermostat | SL | Wiring Centre | 5 | Brown (live) |
| 13 | Dual Channel Programmer | 3 | Wiring Centre | 6 | Brown (live) |
| 14 | Cylinder Thermostat B | C | Wiring Centre | 6 | Brown (live) |
| 15 | Dual Channel Programmer | 1 | Wiring Centre | 7 | Brown (live) |
| 16 | Cylinder Thermostat B | 2 | Wiring Centre | 8 | Brown (live) |
| 17 | Heat-Only Boiler | L | Wiring Centre | 1 | Brown (live) |
| 18 | Heat-Only Boiler | N | Wiring Centre | 2 | Blue (neutral) |
| 19 | Heat-Only Boiler | E | Wiring Centre | 3 | Green/yellow (earth) |
| 20 | Wiring Centre | 8 | Heat-Only Boiler | SL | Orange |
| 21 | Heat-Only Boiler | PL | Circulation Pump | L | Brown (live) |
| 22 | 3-Port Valve | E | Wiring Centre | 3 | Green/yellow (earth) |
| 23 | 3-Port Valve | N | Wiring Centre | 2 | Blue (neutral) |
| 24 | 3-Port Valve | W | Wiring Centre | 5 | Grey |
| 25 | 3-Port Valve | G | Wiring Centre | 7 | Grey |
| 26 | 3-Port Valve | O | Wiring Centre | 8 | Orange |
| 27 | Cylinder Thermostat B | 1 | Wiring Centre | 7 | Brown (live) |
The truth table it must pass
Commissioning is four demand states and four results. The test harness runs this table against the circuit before every release.
| Demand | Result |
|---|---|
| No demand: programmer HW off and CH off (room stat calling, cylinder cold) | Valve rests at B (hot water port); boiler off |
| HW only: programmer HW on (room stat calling, cylinder cold) | Valve stays at B (hot water port); boiler fires |
| CH only, HW timed off: programmer CH on (room stat calling, cylinder cold) | Valve drives to A (heating port); boiler fires |
| CH + HW: programmer HW on and CH on (room stat calling, cylinder cold) | Valve at mid position; boiler fires |
| CH + HW, cylinder now hot (room stat calling) | Valve moves to A (heating port); boiler fires |
| HW on but cylinder hot, CH off (room stat calling) | Boiler off (valve position not asserted by the probe) |
Related
Build it lesson by lesson
- Y-Plan Wiring course
Master the Y-Plan system with hands-on wiring. Connect the 3-port valve and see mid-position operation in action.